Comanche County sees serious storms
Comanche County logged 358 severe weather events between 2015 and 2024, including 185 hail events, 148 damaging wind events and 11 tornadoes. Winter added 14 more rounds of snow, ice or blizzards in that span.

Takes about a minute. No obligation.
Comanche County logged 358 severe weather events between 2015 and 2024, including 185 hail events, 148 damaging wind events and 11 tornadoes. Winter added 14 more rounds of snow, ice or blizzards in that span.
Outdoor equipment takes the hit from hail and wind here, and a furnace that loses power during a winter storm leaves a home without heat until it's back. A quarter of Oklahoma households went at least a full day without power in 2024.
Furnaces in Comanche County start working in November.
Get the tune-up done in October, before the cold and the storms that come with it.




Between visits, change the filter. A dirty filter chokes airflow, and a furnace starved for air runs its heat exchanger hotter than it should. Look at it every month or two and hold it up to a light. If you can't see through it, swap it. Keep the area around the furnace clear, nothing stacked against the cabinet, nothing blocking the return grille. Outside, keep the intake and exhaust vents clear of leaves, nests or snow, since a blocked vent can shut the furnace down or worse. If you smell gas, or if the burner flame looks yellow instead of blue, turn the furnace off and have it looked at. That's not a wait and see.
A tune-up covers what a storm might have already done to the outdoor unit. A tech can check it for hail dents, bent fins, and debris that built up without you noticing, before that damage turns into a bigger repair this winter.
Find a contractor
A furnace doesn't have a drain or an outdoor coil, that's the air conditioner's job, but the filter still decides how hard the heat exchanger has to work. Air gets pulled through the filter, across the heat exchanger, and back out into the house. Block that path with a dirty filter and the exchanger can't shed heat the way it's built to, so it runs hotter on every cycle. Over time that heat stress is what cracks an exchanger. The blower motor feels it too, working harder to push air through a clogged filter than it was designed to. None of this shows up overnight. It shows up as a furnace that cycles more than it used to, or one that's already stressed when the igniter or the flame sensor finally gives out.
The igniter and the flame sensor wear down from doing their job, not from neglect, and neither one gives much notice before it quits. A tech pulls the flame sensor and cleans off the oxide layer that builds up on it, since that coating is what makes a furnace fire up and shut right back down. The igniter gets checked for hairline cracks you would never spot without pulling it. Flue connections get checked too, because a cracked or loose one lets exhaust go somewhere other than outside.
Most of a tune-up is a furnace that passes every check, and that is still worth knowing. A clean flame sensor, a solid igniter, a heat exchanger with no cracks or hot spots means the furnace is good to run hard without a surprise breakdown. The value is having someone who knows what a stressed furnace looks like catch it a season before it strands the house without heat.
Skip enough tune-ups and a furnace doesn't fail all at once. Dust builds up on the burners and inside the blower wheel, and a dirty blower moves less air even running at full speed. The flame sensor's oxide coating gets thicker each season it goes uncleaned, until one day the furnace fires, shuts off after a few seconds, fires again, and gives up. A cracked heat exchanger is the one that matters most, because it's hidden inside the cabinet and keeps running right up until someone finds it or the furnace starts tripping its own safety switch. None of these start as emergencies. They start as small wear nobody was watching, until the furnace is the thing that quits on the coldest night of the year.
A full tune-up starts with the thermostat. A tech checks that it calls for heat properly and that the furnace responds right away, no long delay before it kicks on. On an electric furnace, the heating elements get checked for even heat and for any sign of a burned or weak spot, since one bad element forces the rest to work harder to make up the difference. Amp draw on the blower motor gets measured against what the motor is rated for, because a motor pulling too many amps is wearing out even if it still runs fine today. Electrical connections at the elements and the control board get checked and tightened, since a loose connection there is what causes arcing and burned wiring down the line. Every safety switch gets tested on its own, the limit switch and the sequencer among them, because each one exists to shut the furnace down before a specific failure turns dangerous. On the gas furnaces still out there, the same visit covers the burners, the flame, and the gas pressure, since those systems fail in their own particular ways.