What the cold here does to a heat pump
Heating is the job here, not cooling. The furnace or heat pump runs seven months a year, October through April. Cooling only runs five. Whatever goes in the house earns its keep mostly in winter.
A standard heat pump starts losing ground before the real cold sets in. Below 40°F it puts out less heat than its rating says. Below about 35°F it often needs backup heat to cover the gap. The average overnight low here in December, January and February is 31°F, under both marks. On a typical winter night, a standard heat pump in this county is already past the point where it runs at full strength.
That is not a rare night. The temperature falls to freezing or below about 70 nights a year, under a third of the roughly 210 nights the heat runs, and every one of those nights sits below both the 40°F and 35°F marks. A furnace does not have this problem. It burns gas and makes its full rated heat whether it is 40 outside or 10.
The deep cold that would actually strain a heat pump is rare here. Readings at 0°F or below happen on fewer than one night a year, a small fraction even of the roughly 70 freezing nights. A field test of prototype cold-climate heat pumps found backup heat covering only a small share of the heat used between 0°F and 35°F, and running on backup alone was rare even above 0°F. That is the range this county actually sees.
If a heat pump is on the table, look for the ENERGY STAR Cold Climate label. To earn it, a heat pump has to keep at least 70 percent of its 47°F heating capacity at 5°F, and still deliver at least 1.75 units of heat for every unit of electricity it uses at that temperature, verified by outside testing. A standard model is not built to do either.