What winter here does to a heat pump
Your winter low averages 23°F, and that number matters more than the cost-per-Btu figures above. A standard heat pump starts losing ground below 40°F, putting out less heat than its rating, and below about 35°F it usually needs backup heat to make up the difference. Your average night is below both marks. Over half the nights between October and April, about 125 of them, drop to freezing or lower.
That doesn't mean the heat pump stops working. It means it runs with help for a lot of the winter. The $1.63 per 100,000 Btu figure in the cost band above is the federal minimum heat pump running on its own, with nothing added for that backup heat. Most of your heating season, it won't be running alone.
The one piece of good news: only about one night a year here hits 0°F or below, the temperature where a heat pump struggles most. Field tests of newer cold-climate heat pumps in occupied homes found backup heat carried only a small part of the load between 0°F and 35°F, and running on backup alone was rare above 0°F. If you're looking at a heat pump for this county, that difference between a standard model and one built for cold climates is the one to ask about. ENERGY STAR's Cold Climate rating requires the unit to hold onto most of its heating power and still produce over three-quarters of a unit of heat per unit of electricity at 5°F, verified by outside testing. A standard heat pump isn't built to do that.