What winter here actually asks of a heat pump
A heat pump here will spend most of its winter nights fine on its own. The average overnight low in December, January and February is 34°F, and only about 65 nights a year dip to freezing or below. That matters because the two marks that cause a standard heat pump trouble are 40°F, where its output starts falling short of its rating, and about 35°F, where it often needs backup heat to make up the difference. Bryan County's winter sits right at that line, not deep past it.
Fewer than one night a year here reaches 0°F. That's the number that worries people, and it almost never happens in this county. Field tests of modern cold-climate heat pumps in occupied homes found backup heat carried only a small share of the load between 0°F and 35°F, and running on backup alone was rare even above 0°F. A standard heat pump without that cold-climate rating will lean on backup more than that, but the nights that would force it are rare here too.
If you want a heat pump that barely notices the cold, look for the ENERGY STAR Cold Climate label. To earn it, a heat pump has to deliver at least 1.75 units of heat per unit of electricity at 5°F and hold onto 70 percent of its 47°F capacity at that temperature, checked by outside testing. Bryan County winters don't demand that level of machine, but it removes the question entirely if you'd rather not think about backup heat at all.