What the cold here actually does to a heat pump
Winter here is long but not harsh, and that's the whole case. Heat runs about six months, November through April, and the overnight low averages 32°F across December, January and February. That's cold enough to use a furnace most nights, but it's not brutal cold. Nights at or below freezing happen about 70 times a year, and only about one of those a year drops to 0°F or below. Almost all your cold nights sit in that 32-and-just-below range, not deep freeze territory.
That matters because of how a heat pump behaves in the cold. A standard one starts falling short of its rated heat output once it's below 40°F outside, and it often needs backup heat once it's below about 35°F. Your average winter low of 32°F sits below both marks, so on a typical winter night here, a standard heat pump is working below its rating and may be leaning on backup heat to make up the difference. That's true of nearly every one of those 70 freezing nights, not just the rare hard freeze.
This is less of a problem than it sounds. Oklahoma winters rarely ask a heat pump to do its hardest work. With fewer than one night a year at 0°F or below, you aren't pushing a heat pump into the range where it struggles most. A field test of cold-climate heat pumps in occupied homes found backup heat covered only a small share of total heat between 0°F and 35°F, and running on backup alone was rare even above 0°F. If you buy a heat pump built to the ENERGY STAR Cold Climate spec, which has to hold at least 70 percent of its 47°F capacity and still produce 1.75 units of heat per unit of electricity at 5°F, the backup heat kicks in even less. Given how rarely this county sees real cold, that spec is more capacity than most years will ask for.